Skip to content
ShopStanding seam sheetG-Fold (Double Standing Seam) Developed Width 62.5
FL-GFG-Fold (Double Standing Seam) Developed Width 62.5
G-fold

FL-GF

G-Fold (Double Standing Seam) Developed Width 62.5

Double standing seam sheet G-fold, developed width 62.5.

8.13€/m

Price incl. 25 % Croatian VAT • net: 6.50 €/m

Available on request
Quantity

Category

Standing seam sheet

Unit

per linear metre

Developed width

625 mm

Quality guarantee

Steel S320GD, Z275 galvanising to EN 10346
Certificates available on request
Delivery: 3–7 working days
Direct from the factory in Đakovo

Category guide

Standing seam sheet — application, standard and installation

Where it is used

Standing seam sheet (G-fold, double standing seam) is a covering with longitudinal standing seams and no visible screws: it is used on roofs of low pitch, on rounded and curved planes, on domes and on facades where a smooth, narrow strip without corrugations is wanted. It is laid on a solid substrate and fixed with clips concealed in the seam; it is offered on request, to a roof drawing.

The standard and what it guarantees

The sheet is steel S320GD, galvanising Z275 (275 g of zinc per m², both sides) to EN 10346, polyester coating 35 µm. A standing seam covering is not self-supporting — it rests on a solid substrate, so EN 14782 (self-supporting profiles) does not apply to it, but rather the trade rules for sheet-metal coverings on a substrate; EN 10346 guarantees the steel substrate and the zinc thickness.

What to watch out for during installation

A solid boarded substrate with a separating (structured) layer that separates the sheet from the timber and drains the condensate. The strips are fixed with fixed clips over part of their length and with sliding clips over the rest, so that the sheet can lengthen in the heat without buckling; the seam is closed by hand or by machine against the direction of the prevailing wind. The sheet is not pierced on the water side.

Questions and answers

Frequently asked questions: Standing seam sheet

Why does standing seam sheet have no visible screws?

Because the strips are fixed with clips — steel tabs that are nailed to the substrate and folded into the seam, so the closed seam covers them. The sheet is not pierced on the water side, and sliding clips allow it to lengthen in the heat. The sheet is S320GD Z275 to EN 10346.

What substrate does standing seam sheet need?

A solid substrate — boards or panels — with a separating layer that separates the sheet from the timber and lets the condensate through. A standing seam covering is not self-supporting like trapezoidal sheet T-35 and T-45 to EN 14782; the load capacity comes from the substrate, the sheet provides the weathertightness.

What is G-fold sheet made of and how strong is its protection?

Of steel S320GD with Z275 galvanising — 275 g of zinc per m², both sides, to EN 10346 — and a polyester coating of 35 µm in a RAL colour. On request it is also made of aluminium, copper or stainless steel from the flat sheet range.